Cold aisle cabinet
Product Features:
Isolation of hot and cold air, no turbulence, no short circuit, high refrigeration efficiency, saving energy consumption costs;
Good heat dissipation effect, significantly improving the cooling efficiency compared to a single cabinet, increasing the installation density of cabinet equipment, and saving space in the computer room;
The top plate of the channel is attached to the frame of the top cover by a magnetic lock, and the power supply of the magnetic lock is controlled by the fire protection system. When a fire alarm occurs, the fire protection system in the computer room forcibly shuts off the power supply, and the top cover opens under the action of gravity to carry out gas fire protection in the cold channel area, which is safe and reliable;
Modular installation, all installations of the entire system are processed in a modular form by the factory and delivered to the site for easy installation;
The two ends of the passage are equipped with sliding doors or electric doors, which do not occupy the space of the passage. They can be made of sheet metal doors with observation windows or floor to ceiling glass doors;
Equipped with digital password lock or user specified lock type;
The top of the channel is covered with transparent glass, which is easy for personnel to enter and exit at a height above the ground after opening, without causing any harm to the operator;
Install energy-saving lamps at the top of the channel;
The connection between the top cover component of the channel and the front and rear door components is equipped with sealing strips, greatly improving the cooling efficiency;
Install temperature, humidity, smoke and other sensors in the channel to collect signals for precision air conditioning to adjust the temperature and humidity in the channel and transmit control signals to the fire protection system;
An optional camera can be installed inside the channel, and a temperature and humidity display screen can be installed above the door panel for real-time monitoring and control of the channel interior.
Standard: Compliant ANSI/EIA RS-310-D、IEC297-2、DIN41491:PART1、DIN41494:PART7、GB/T3047.2 - 92 Standard; Compatible with ETSI standards.
Material: Square hole strip, fingerprint resistant galvanized aluminum plate for installation beam; Other SPCC high-quality cold-rolled steel plates.
Thickness: Square hole strip, top cover 2.0mm; skeleton, installation beam 1.5mm; other SPCC 1.2mm.
Surface treatment: square hole strips, natural color of installation beams, others: degreasing, phosphating, electrostatic spraying.



Magnetic lock parameters:
Model: VN-180
Working voltage: DC-12V
Maximum adsorption capacity: 180KG (maximum adsorption capacity for objects with flat surfaces is 180KG)
Introduction to Airflow Control:
The computer room air conditioner sends cold air through the static floor into the cold aisle;
Cold air only enters from the front end of the server through its heat dissipation holes, taking away the heat generated by the server and then being discharged from the back end;
The gap between servers is sealed with blind plates.

Cold aisle case photo









Online Consultation
No Defect on Products, No Claim from Customers" is the goal we pursue. We will continue following international standards to provide customers with satisfied products. All above guarantee the high quantity of our products.
TOTEN Co.
They have rich craftsmanship knowledge and a strong sense of quality and self-inspection.
Company Address
Contact Number
Follow us
Consultation Message
Related Recommendations
LOGO
This stunning beach house property is a true oasis, nestled in a serene coastal community with direct access to the beach.
Opening Hours
Monday - Friday : 9AM to 5PM
Sunday: Closed
Closed during holidays
Contact
+18888888888
hezuo@eyingbao.com123 West Street, Melbourne Victoria 3000 Australia